Structural design knowledge: the use of steel frame buildings - support structure requirements?

Time:[2015-1-7]  Hits:4705

Structural design knowledge: the use of steel frame buildings - support structure requirements?

Steel frame houses using - support structure requirements?
A support frame in the arrangement of the two directions are advised fundamental symmetry between floor support frame aspect ratio of not more than three.
Two three, four and not more than 50m in height should adopt steel center support, may also have eccentric bracing, buckling restrained braces and other energy dissipation.
3 center support frame cross bracing should be adopted, the word can also be used to support or monoclinic rod support, should not be used K-shaped support; support should meet at the intersection of the axis of the beam-column members axis, eccentric deviation from the intersection when the support should not exceed the width of the rod, and should be included in the resulting additional moment. When using only the central support of the tension rod monoclinic system, should also be set in different tilt directions of two diagonals, and each group in different directions monoclinic rod cross-sectional area difference between the area of the projection in the horizontal direction is not greater than 10%.
Each supporting four eccentrically braced frames should have at least one end connected to the frame beam and the intersection between the supporting beams and columns with the same cross between or within other support to form the beam energy dissipation beam segment intersections.
5 When using the buckling restrained braces, the word should be used to support, arranged in pairs monoclinic rod support and other forms should not be used in the angle between the K-shaped or X-shaped should support and column 35 ° ~ 55 °. When the buckling restrained braces compression, its design parameters, performance testing and calculation methods as the two parts of energy dissipation requirements can design.

Copyright:佛山市胜邦钢结构有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粤ICP备13078463号
化工厂防雷检测仪| 输变电工程| 行星齿轮减速机| 高密度| 耐腐蚀真空泵| 三洋药品冷藏箱| MonelK500合金零切圆钢| 超音波熔接机| 涡轮| 不锈钢螺旋输送机| ASP23粉末钢| 淄博数控机械| 江苏40cr厚壁合金管| FEVIK冻干机| 学生课桌椅| 美的生物医疗超低温冰箱| Edwards真空泵维修| 反向镊子| 电导测试仪| 1168多功能高空接线钳| 管道警示带| SUN插装阀| 高温氧化铝微粉| 叉车厂家价格多少钱一台| 模块电源| 透浦式中压鼓风机| 金属焊接机| 高低温实验箱| 微机热释光剂量仪(百科)| UVP分子杂交箱| 硅橡胶加热器| 超高温石墨化炉| 水压力传感器| 钢结构厂房| 变电所运维云平台| 电子检重秤| 通道加压液体自动进样器| 无线二氧化碳探测器| 二手不锈钢冷凝器现货| 粉尘防爆鼓风机| 人造草坪|